Spectrometer Selector
Spectrometer Specifications
Best matches
Ibsen Photonics standard OEM spectrometers you can configure:
FREEDOM HR-DUV
FREEDOM HR/C · LIBS, UV
- Wavelength range
- 178 – 409 nm
- Resolution (nm)
- 0.30
- Detector
- Hamamatsu S11156-2048-02
FREEDOM HR-UV/C-UV
FREEDOM HR/C · UV, LIBS
- Wavelength range
- 190 – 435 nm
- Resolution (nm)
- 0.15 – 0.90
- Detector
- Hamamatsu S11639N-01 / S13496 / S10420-1106 / S11156-2048-02
FREEDOM UV
FREEDOM · UV
- Wavelength range
- 190 – 435 nm
- Resolution (nm)
- 0.7 – 4.9
- Detector
- Hamamatsu S11639N-01 (101) / S10420-1006 (305) / S11156-2048-02 (380)
FREEDOM UV-NIR
FREEDOM Broadband · UV-NIR, UV-VIS
- Wavelength range
- 190 – 1100 nm
- Resolution (nm)
- 1.8 – 12.2
- Detector
- Hamamatsu S11639 (101) / S10420 (315) / S11156 (380)
FREEDOM UV-VIS
FREEDOM Broadband · UV-VIS
- Wavelength range
- 190 – 850 nm
- Resolution (nm)
- 1.3 – 10.9
- Detector
- Hamamatsu S11639 (101) / S10420 (315) / S11156 (380)
COMPACT ROCK VIS
COMPACT ROCK · VIS
- Wavelength range
- 360 – 830 nm
- Resolution (nm)
- 0.8 – 3.8
- Detector
- Hamamatsu S13496 / S11639N-01 / S10420-1006 / S11156-2048-02
FREEDOM HR-VIS/C-VIS
FREEDOM HR/C · VIS, LIBS
- Wavelength range
- 360 – 830 nm
- Resolution (nm)
- 0.30 – 1.6
- Detector
- Hamamatsu S11639N-01 / S13496 / S10420-1106 / S11156-2048-02
FREEDOM VIS
FREEDOM · VIS
- Wavelength range
- 360 – 830 nm
- Resolution (nm)
- 1.3 – 8.8
- Detector
- Hamamatsu S11639N-01 (101) / S10420-1006 (305) / S11156-2048-02 (380)
PEBBLE VIS
PEBBLE · VIS
- Wavelength range
- 360 – 830 nm
- Resolution (nm)
- 5.2 – 11.5
- Detector
- Hamamatsu S14739-20 (CMOS, uncooled)
FREEDOM HR-XVIS/C-XVIS
FREEDOM HR/C · VIS, LIBS, VIS-NIR
- Wavelength range
- 415 – 957 nm
- Resolution (nm)
- 0.40 – 1.9
- Detector
- Hamamatsu S11639N-01 / S13496 / S10420-1106 / S11156-2048-02
FREEDOM HR-VIS-NIR/C-VIS-NIR
FREEDOM HR/C · VIS-NIR, LIBS
- Wavelength range
- 475 – 1100 nm
- Resolution (nm)
- 0.50 – 2.1
- Detector
- Hamamatsu S11639N-01 / S13496 / S10420-1106 / S11156-2048-02
FREEDOM VIS-NIR
FREEDOM · VIS-NIR
- Wavelength range
- 475 – 1100 nm
- Resolution (nm)
- 1.7 – 12.5
- Detector
- Hamamatsu S11639N-01 (101) / S10420-1006 (305) / S11156-2048-02 (380)
COMPACT ROCK VIS-NIR
COMPACT ROCK · VIS-NIR
- Wavelength range
- 500 – 1100 nm
- Resolution (nm)
- 1.0 – 4.7
- Detector
- Hamamatsu S13496 / S11639N-01 / S10420-1006 / S11156-2048-02
PEBBLE VIS-NIR
PEBBLE · VIS-NIR
- Wavelength range
- 500 – 1100 nm
- Resolution (nm)
- 6.7 – 15.9
- Detector
- Hamamatsu S14739-20 (CMOS, uncooled)
EAGLE Raman HR 532
EAGLE Raman · Raman
- Wavelength range
- 532 – 732 nm
- Resolution (nm)
- 0.24 – 0.47
- Detector
- Hamamatsu S11850-1106 / S14651-2048 (TE-cooled +5 °C)
EAGLE OCT-S-140
EAGLE OCT · OCT
- Wavelength range
- 780 – 920 nm
- Resolution (nm)
- 0.09
- Detector
- Teledyne e2v OctoPlus CMOS (2048 px)
EAGLE Raman HR 785
EAGLE Raman · Raman
- Wavelength range
- 785 – 1080 nm
- Resolution (nm)
- 0.36 – 0.67
- Detector
- Hamamatsu S11850-1106 / S14651-2048 (TE-cooled +5 °C)
EAGLE C-OCT-S-90
EAGLE OCT · OCT
- Wavelength range
- 795 – 885 nm
- Resolution (nm)
- 0.05
- Detector
- Hamamatsu S17122 CMOS (M-DISB-191 camera)
EAGLE OCT-S-M-90
EAGLE OCT · OCT
- Wavelength range
- 795 – 885 nm
- Resolution (nm)
- 0.05
- Detector
- Teledyne e2v OctoPlus CMOS (2048 px)
EAGLE OCT-S-90
EAGLE OCT · OCT
- Wavelength range
- 800 – 890 nm
- Resolution (nm)
- 0.05
- Detector
- Teledyne e2v OctoPlus CMOS (2048 px)
EAGLE Raman-S
EAGLE Raman · Raman
- Wavelength range
- 800 – 1100 nm
- Resolution (nm)
- 0.4 – 0.7
- Detector
- Andor iVac 316 BT-CCD (−60 °C cooled)
EAGLE OCT-S-40
EAGLE OCT · OCT
- Wavelength range
- 820 – 860 nm
- Resolution (nm)
- 0.02
- Detector
- Teledyne e2v OctoPlus CMOS (2048 px)
EAGLE C-OCT-S-28
EAGLE OCT · OCT
- Wavelength range
- 826 – 854 nm
- Resolution (nm)
- 0.015
- Detector
- Hamamatsu S17122 CMOS (M-DISB-191 camera)
ROCK NIR
ROCK · NIR
- Wavelength range
- 900 – 1700 nm
- Resolution (nm)
- 3.3 – 10.0
- Detector
- Hamamatsu G11508-256 / -512 (1-stage TE-cooled InGaAs)
PEBBLE NIR
PEBBLE · NIR
- Wavelength range
- 950 – 1700 nm
- Resolution (nm)
- 9.5 – 12.9
- Detector
- Hamamatsu G13913 (uncooled InGaAs)
ROCK XNIR
ROCK · NIR
- Wavelength range
- 1100 – 2100 nm
- Resolution (nm)
- 5.6 – 12.8
- Detector
- Hamamatsu G11477-256 / -512 (2-stage TE-cooled InGaAs)
Want to know more?